Abstract:The conversion and modification of a 65 t/h oil-fired boiler at Jihua Refinery to fire coal water slurry is described along with a brief account of the latter's discharge, storage and transportation system, the boiler front system components, slag and dust removal system. Moreover, analyzed are the modified-boiler operating conditions, economic and social benefits achieved and future use prospects of such modifications. The actual results of conversion of the above-cited boiler indicate that its load can be higher than 60 t/h, combustion efficiency above 97% and thermal efficiency greater than 88.5%.