Combustion Properties of Sludge Coal Water Slurry in a 3. 2 MW Horizontal Furnace

HU Qinhai,MENG Yuanyuan,ZHU Jianhang,WANG Dan,LIU Jianzhong,ZHOU Junhu,CEN Kefa
DOI: https://doi.org/10.13671/j.hjkxxb.2011.02.027
2011-01-01
Abstract:Combustion experiments were conducted on sludge-coal water slurry (S-CWS) in a 3.2 MW horizontal furnace to investigate its feasibility for industrial application. Combustion properties such as ignition,temperature field and combustion efficiency were analyzed and compared with data for Datong bituminous coal water slurry. Results showed that S-CWS with mass ratio of 10% could be easily set ablaze. With ample flame in uniform distribution,the flame temperature came up to 1200~1300 ℃ in the main combustion chamber area. Moisture transference produced plentiful blowholes which would be conducive to combustion and burnout of S-CWS particles. The carbon content of particulate matter declined along the axe and the combustion efficiency reached as high as 99.75%. Overall,the combustion of S-CWS was pretty good,which even better than Datong bituminous coal water slurry and could offer a feasible new way for utilization of municipal sewage sludge.