Study of Degradation of P-Chlorophenol in Aqueous Solution with Pulsed Corona Discharge Plasma

陈银生,张新胜,戴迎春,袁渭康
DOI: https://doi.org/10.3321/j.issn:1003-9015.2003.01.013
2003-01-01
Abstract:Organic compounds in the aqueous solution can be degradated efficiently through the oxidation reactions of p-chlorophenol and non-thermal plasma formed due to the direct pulsed high-voltage corona discharge in the wastewater. Investigation showed that the degradation of p-chlorophenol in wastewater with various discharge parameters is a first-order reaction, C=C0e-kt. The degradation rate of p-chlorophenol can be increased by increasing the peak voltage Vp and the repetition rate of pulse f. However, increasing the distance l between the discharge electrode and the ground electrode will decrease severely the degradation rate of p-chlorophenol. When certain discharge parameters are applied in degradation, the degradation rate constant k of p-chlorophenol could be described as: k=10-8(Vp)4.22,k=4.78×10-6f 1.81,and k=-1.184×10-2lnl+0.02153.
What problem does this paper attempt to address?