Influence of Discharge Reactor Design on the NO Removal Rate with Dielectric Barrier Discharges

赵文华,张旭东
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.11.020
2003-01-01
Abstract:A high voltage power system and a coaxial cylinder-tube dielectric barrier discharge reactor were designed to study the influence of the discharge reactor design on the NO removal by the discharge of a non-thermal plasma. The investigated discharge reactor design parameters included the thickness and dielectric constant of the dielectric layer, the central electrode diameter, and the internal diameter of the dielectric barrier tube. The experimental results show that the NO removal rate decreases with increasing dielectric layer thickness but increases with increasing dielectric constant of the dielectric material. The size of the central electrode and the dielectric tube internal diameter also influence the NO removal rate. The central electrode diameter and the dielectric tube internal diameter should be optimized to maximize the NO removal rate.