Reduced Rating of Active Filter in Hybrid Power Filter

邓占锋,朱东起,姜新建
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.03.004
2003-01-01
Abstract:A novel hybrid power filter topology was developed to economically filter harmonic currents in power systems. The rating and cost of its active filter are less than conventional hybrid filters. A passive filter maintains the network voltage while the fundamental resonance branch shunts the reactive current, which greatly reduces the rated current and voltage of the active filter. With the control strategy, the filter keeps the harmonic system voltage from generating harmonic currents and effectively prevents the harmonic load current from flowing to the upstream system. PSCAD/EMTP simulation results show that the active filter rating accounts for only 2.11% of the total rating while the THD (total harmonic distortion) of the system current is reduced to 4.15% with the filter.
What problem does this paper attempt to address?