Calculation of Temperature Field of Dry-Type Air-Core Damping Reactor Based on Coupled Method

刘志刚,王建华,耿英三,武安波,史仓会
DOI: https://doi.org/10.3321/j.issn:0253-987X.2003.06.017
2003-01-01
Abstract:A coupled magnetic-circuit-fluid-thermal finite element model is proposed for thermal analysis of dry-type air-core damping reactor. The magnetic field, inductance and current of damping reactor are computed by couple magnetic-circuit firstly, and then Joule heat obtained from magnetic-circuit is applied to the calculation of fluid-thermal field as heat source. The temperature field of an air-core damping reactor is calculated and the result agrees with the physical measurement. Using this method, the thermal analysis of air-core damping reactor is performed without specifying convection heat transfer coefficients at its development stage. Therefore, the experimental cost of air-core damping reactor is decreased and the design cycle is shortened.
What problem does this paper attempt to address?