A Voltage-Based Multiple Fault Diagnosis Approach for Cascaded H-Bridge Multilevel Converters
Dong Xie,Huai Wang,Xinglai Ge,Qingli Deng,Bin Gou,Lei Ma
DOI: https://doi.org/10.1109/jestpe.2021.3108895
IF: 5.462
2021-01-01
IEEE Journal of Emerging and Selected Topics in Power Electronics
Abstract:This article proposes a fast and robust open-circuit fault diagnosis method without additional sensors for cascaded H-bridge multilevel converters (CHBMCs). The method is based on the error between the actual input-side voltage and the estimated one, with one detection threshold and <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="2.557ex" height="2.176ex" style="vertical-align: -0.338ex;" viewBox="0 -791.3 1101 936.9" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMAIN-32" x="0" y="0"></use> <use xlink:href="#MJMATHI-6E" x="500" y="0"></use></g></svg></span> comparators in <span class="mjpage"><svg xmlns:xlink="http://www.w3.org/1999/xlink" width="1.395ex" height="1.676ex" style="vertical-align: -0.338ex;" viewBox="0 -576.1 600.5 721.6" role="img" focusable="false" xmlns="http://www.w3.org/2000/svg"><g stroke="currentColor" fill="currentColor" stroke-width="0" transform="matrix(1 0 0 -1 0 0)"> <use xlink:href="#MJMATHI-6E" x="0" y="0"></use></g></svg></span> cascaded H-bridges. Benefitted from the simple design of the fault location, spike elimination, and parameter estimation, with the lower implementation burden, the single and multiple faults in arbitrary positions are accurately identified within a fundamental cycle, and the diagnostic robustness is guaranteed under different transient changes. In view of the low complexity, the proposed scheme can be easily applied to the CHBMCs with arbitrary modules. The experimental results from a CHBMC prototype verify the effectiveness of the proposed method under different operating conditions and fault scenarios.<svg xmlns="http://www.w3.org/2000/svg" style="display: none;"><defs id="MathJax_SVG_glyphs"><path stroke-width="1" id="MJMAIN-32" d="M109 429Q82 429 66 447T50 491Q50 562 103 614T235 666Q326 666 387 610T449 465Q449 422 429 383T381 315T301 241Q265 210 201 149L142 93L218 92Q375 92 385 97Q392 99 409 186V189H449V186Q448 183 436 95T421 3V0H50V19V31Q50 38 56 46T86 81Q115 113 136 137Q145 147 170 174T204 211T233 244T261 278T284 308T305 340T320 369T333 401T340 431T343 464Q343 527 309 573T212 619Q179 619 154 602T119 569T109 550Q109 549 114 549Q132 549 151 535T170 489Q170 464 154 447T109 429Z"></path><path stroke-width="1" id="MJMATHI-6E" d="M21 287Q22 293 24 303T36 341T56 388T89 425T135 442Q171 442 195 424T225 390T231 369Q231 367 232 367L243 378Q304 442 382 442Q436 442 469 415T503 336T465 179T427 52Q427 26 444 26Q450 26 453 27Q482 32 505 65T540 145Q542 153 560 153Q580 153 580 145Q580 144 576 130Q568 101 554 73T508 17T439 -10Q392 -10 371 17T350 73Q350 92 386 193T423 345Q423 404 379 404H374Q288 404 229 303L222 291L189 157Q156 26 151 16Q138 -11 108 -11Q95 -11 87 -5T76 7T74 17Q74 30 112 180T152 343Q153 348 153 366Q153 405 129 405Q91 405 66 305Q60 285 60 284Q58 278 41 278H27Q21 284 21 287Z"></path></defs></svg>
engineering, electrical & electronic