Control of Cascaded H-bridge Multi-Level Inverters in Fault

卫三民,刘丛伟,孙旭东,李发海
DOI: https://doi.org/10.3321/j.issn:1000-0054.2003.03.024
2003-01-01
Abstract:The fault tolerance and reliability of high voltage cascaded Hbridge multilevel inverters were improved by an adjustable switched state control method (ASSCM) developed by analyzing the effects of malfunctioning Hbridge cells on the voltage space vectors. Detailed equation and ASSCM results are given for a sevenlevel cascaded Hbridge multilevel inverter as an example. Compared with existing control methods, this method generates higher voltage space vector magnitudes and markedly reduces the influence of inverter problems on motor operation in most Hbridge cell fault modes while keeping the motor voltage symmetrical. Simulations and tests on a prototype show the effectiveness of the proposed method.
What problem does this paper attempt to address?