SYNCHRONOUS MEASUREMENT PRECISION OF PHASOR MEASUREMENT UNIT

杨贵玉,江道灼,邱家驹
DOI: https://doi.org/10.3321/j.issn:1000-1026.2003.14.013
2003-01-01
Abstract:The main error-factors of phasor measurement unit (PMU) based on global position system (GPS) and phase locked loop (PLL) are analyzed and simulated. The result indicates that amplitude error is much smaller than phase error, and the synchronous method error for different sites is much smaller than its synchronized measurement error. The later is mainly caused by frequency tracking and measurement of PMU, the signal filter delay and the digital algorithm. Some existed problems are investigated when the PLL chip is used to lock and track signal frequency and the frequency changes quickly. The finial conclusion is that the precision of PMU can be achieved to l°if the accuracy of frequency tracking and measurement is ensured.
What problem does this paper attempt to address?