Research on flow pattern visualization systembased on electrical capacitance tomography

谢代梁,王保良,黄志尧,李海青
DOI: https://doi.org/10.3785/j.issn.1008-973X.2002.01.005
2002-01-01
Abstract:The principle of the Electrical Capacitance Tomography (ECT) system is introduced. A flow pattern visualization system of AC-based Electrical Capacitance Tomography technique with high data acquisition rate was developed. An integrative ECT system was designed successfully due to the modularized system structure. The performance of the imaging system was improved and some problems in the industrial application of ECT such as decreasing the volume of the system, improving the speed of data acquisition and transferring could be solved. The weighted back projection algorithm based on finite element simulation was selected as the image reconstruction algorithm to satisfy the demand of real-time flow pattern visualization. The speed of image reconstruction was greater than 20 frames per second. Experiments were carried out on a gas/oil pipe line. Via a PC adapter card and a serial communication unit the distance of data transferring by twist line was more than 50 meters. The flow patterns were visualized correctly. The results showed that the design was successful.
What problem does this paper attempt to address?