Study of magnetic signals behavior at groove defect by tensile stress during online measurement of Q345R steel
Yinhu Xu,Luning Zhao,Jinlin Zhong,Kunshan Xu,Xin Zhang,Tailai Li,Jie Liu
DOI: https://doi.org/10.1016/j.jmmm.2023.171114
IF: 3.097
2023-11-01
Journal of Magnetism and Magnetic Materials
Abstract:To study the influence of external loading on the magnetic signal at the defect location of the component, Q345R steel was selected to make a groove defect specimen for axial tensile testing. The magnetic behavior of the specimens containing different initial magnetization strengths under different stress states (elastic deformation stage, yielding stage, strengthening stage, and fracture stage) was studied in comparison. The result showed that the value of the tangential component Hxave in the nondestructive region gradually decreased with the increase of the stress loading in the elastic loading stage, however, the tangential component Hxave at the defect location of the specimens had different variation patterns due to the different initial magnetization strengths. When the load was loaded to the yielding stage, the magnetic signals remained stable, and Hxave increased again in the strengthening stage and completed the excitation of the magnetic signals in the fracture stage. By analyzing the magnetic memory field parameters throughout the loading process, it can be found that the variation patterns were consistent despite the different initial magnetization intensities of the specimens. The above findings are of great significance for assessing the stress state of defects in ferromagnetic materials.
materials science, multidisciplinary,physics, condensed matter