DYNAMIC PARAMETER IDENTIFICATION OF THE STEAM TURBINE-GENERATOR BY LOAD REJECTION TEST USING DYNAMOMETRY METHOD

于达仁,王西田,崔涛
DOI: https://doi.org/10.3321/j.issn:1000-1026.2002.01.007
2002-01-01
Abstract:According to the known mathematic model of stream turbine-generator, the load-rejection test using dynamometry method is applied to dynamic parameter identification of stream turbine-generator after the parameters are analyzed. Moreover, whether the parameters can be identified separably is also discussed. Genetic algorithms are chosen as the identification algorithms with good results. The identified parameters can be used for dynamic characteristic analysis of such processes as speed runaway and so on, which is significant for the improvement of technology and economic benefits of load-rejection test using dynamometry.
What problem does this paper attempt to address?