Estimation of Graphite Particle Size Distribution in HTR-10 Helium Loop

于溯源,华宏亮
DOI: https://doi.org/10.3969/j.issn.0258-0926.2001.05.007
2001-01-01
Abstract:Graphite is used as the reactor structural material and helium is used as the primary coolant in the 10 MW High Temperature Reactor Test Module (HTR-10) built at Tsinghua University. However graphite particles are produced in the primary helium loop due to the friction and wear. The particle growth and distribution of the particles are studied. A simulation method, based on the particle dynamics equation and the discrete-sectional model (DSM), was verified by a typical example. The graphite particle concentration is so low that the time-lag to achieve the self-preserving distribution is too long. The graphite particle size is 10-20 μm and the particle mean diameter is about 12.9 μm.