The intraocular lens power calculation formula in high myopia and its verification

Jinhui Dai,Renyuan Chu,Guosheng Lu
2000-01-01
Abstract:Objective: To explore a new intraocular lens (IOL) power calculation formula which is more accurate in high myopia. Methods: 176 highly myopic eyes having undergone cataractous surgery were selected for study. A new formula was obtained based on the multiple regression analysis of the 176 eyes by SAS statistical software. 80 highly myopic eyes having undergone cataractous surgery were selected for verification. SRK-II formula was selected as contrast to verify the accuracy of the new formula. Results: The results showed that the new formula named SCDK formula was divided into two parts according to axial length. Compared with the SRK-II formula, the corrected value in the SCDK formula was more by -0.96 for axial length of 26 mm to 30 mm and -0.49 for axial length above 30 mm. In the verification group, the mean absolute refractive error and the prediction error greater than 2 D of the SRK-II formula is higher than that of SCDK formula. Conclusion: The SCDK formula is more accuracy than SRK-II formula in high myopia.