Abstract:Purpose: The proper selection of an intraocular lens power calculation formula is an essential aspect of cataract surgery. This study evaluated the accuracy of artificial intelligence-based formulas. Design: Systematic review. Methods: This review comprises articles evaluating the exactness of artificial intelligence-based formulas published from 2017 to July 2023. The papers were identified by a literature search of various databases (Pubmed/MEDLINE, Google Scholar, Crossref, Cochrane Library, Web of Science, and SciELO) using the terms "IOL formulas", "FullMonte", "Ladas", "Hill-RBF", "PEARL-DGS", "Kane", "Karmona", "Hoffer QST", and "Nallasamy". In total, 25 peer-reviewed articles in English with the maximum sample and the largest number of compared formulas were examined. Results: The scores of the mean absolute error and percentage of patients within ±0.5 D and ±1.0 D were used to estimate the exactness of the formulas. In most studies the Kane formula obtained the smallest mean absolute error and the highest percentage of patients within ±0.5 D and ±1.0 D. Second place was typically achieved by the PEARL DGS formula. The limitations of the studies were also discussed. Conclusions: Kane seems to be the most accurate artificial intelligence-based formula. PEARL DGS also gives very good results. Hoffer QST, Karmona, and Nallasamy are the newest, and need further evaluation.
medicine, general & internal
What problem does this paper attempt to address?
The problem that this paper attempts to solve is how to select the refractive power calculation formula of intraocular lens (IOL) more accurately in cataract surgery. Specifically, the author evaluated the accuracy of these formulas by systematically reviewing the IOL refractive power calculation formulas based on artificial intelligence (AI). The goal of the paper is to compare all existing AI - based IOL refractive power calculation formulas, including hybrid formulas, to provide an up - to - date review. ### Background and Problem In cataract surgery, selecting an appropriate IOL refractive power calculation formula is crucial for achieving good postoperative visual acuity. However, existing studies show that only about 70% - 80% of eyes can achieve a refractive error within the predicted ±0.50 D after surgery. This problem has prompted researchers to develop new methods to improve the accuracy of IOL refractive power calculation. ### Research Purpose This article aims to compare the accuracy of all existing AI - based IOL refractive power calculation formulas, including pure AI formulas and hybrid formulas. By systematically reviewing relevant literature, the author hopes to provide a comprehensive reference for clinicians to select the most appropriate formula in practical applications. ### Method The study adopted the method of systematic review, following the PRISMA guidelines. The author searched relevant literature published from 2017 to July 2023, using multiple databases (such as PubMed/MEDLINE, Google Scholar, Crossref, Cochrane Library, Web of Science, and SciELO), and searched for relevant articles by keywords. Finally, the author selected 25 English peer - reviewed articles for detailed analysis. ### Results The research results show that the Kane formula exhibited the smallest mean absolute error (MAE) in most studies and the highest proportion of patients within the error ranges of ±0.5 D and ±1.0 D. Next was the PEARL - DGS formula. In addition, the Hoffer QST, Karmona, and Nallasamy formulas are relatively new formulas and require further evaluation. ### Conclusion The Kane formula seems to be the most accurate AI - based IOL refractive power calculation formula at present. The PEARL - DGS formula also shows very good results. The Hoffer QST, Karmona, and Nallasamy formulas are newer formulas, and more research is needed in the future to verify their accuracy. ### Keywords Artificial intelligence; Phacoemulsification; Intraocular lens refractive power calculation formula; Kane formula Through this paper, the author hopes to provide a comprehensive reference for ophthalmologists, helping them select the most appropriate IOL refractive power calculation formula in clinical practice, thereby improving the success rate of surgery and patient satisfaction.