Fracture Toughness of Bainite Ductile Iron Obtained by Continuously Quenching

WEI Bingqing,LIANG Ji,WU Dehai,FU Chengsong,GU Chen,DONG Manlin
DOI: https://doi.org/10.3321/j.issn:1000-0054.1999.02.012
1999-01-01
Abstract:The fracture toughness of the wear resistant bainite ductile iron has been investigated. The effects of specimen size on fracture toughness have been studied by measurements of two different size samples. By comparing fatigue crack with electrosparking crack, the effects of crack tip on fracture toughness of ductile iron have been studied. The graphite globularity quality of ductile iron with fracture toughness has been discussed. The experimental results indicate that the fatigue crack as well as the size of samples has little effect on fracture toughness of ductile iron, but the graphite globularity quality has much effect on fracture toughness. The better the sample quality, the higher the fracture toughness.
What problem does this paper attempt to address?