Measurement method of the rolling angle

Chunyong Yin,Guangping Xie,Xiangyin Cheng
1996-01-01
Abstract:For coordinate measurement machine (CMM) and machine tools, the accuracy is limited mainly by Abbe-errors which come from pitching yawing and rolling. In order to correct Abbe-errors, these angles must be measured precisely. The pitching and yawing angles can be measured by the interferometer available, but rolling angle was not dynamically measured yet. A dynamically measurement method of rolling angles is introduced, which is based on polarization testing and magneto-optic modulation. The drift from Faraday cells is compensated by the feed-back method, and the structure of the Faraday cells is optimized by the finite element method, therefore the resolution is 0.1 second, the drift angle is 0.15 second/h.
What problem does this paper attempt to address?