Experimental investigation on the wall temperature characteristics and critical heat flux in a horizontal v-shaped tube

JianXue Zheng,Jiyuan Song,Tingkuan Chen
1995-01-01
Abstract:The experimental parameters are: Pressure 4-14MPa, mass velocity 400-1000kg/(m 2��s), Inlet quality -0.328-0.98 and heat flux 0-350 kW/m 2. The diameter of the tube is 32mm with 3mm thickness and the inclined angle of the tube ��=10��. Under these conditions, the influence of pressure, mass velocity, inlet quality and heat flux on the wall temperature of the tube was investigated. According to the experimental results, correlations to predict heat flux are obtained. These correlations can be used to predict the conditions of heat transfer crisis at the upstream and downstream of the bend of the horizontal V-shaped tube, supplying useful base for the design and operation of the horizontal V-shaped buried tubes in fluidized bed combustion boiler and the slag screens at the exit of the boiler furnace, and so on.