An Investigation on Heat Transfer Characteristics of Different Pressure Steam-Water in Vertical Upward Tube

Xiaojing Zhu,Qincheng Bi,Dong Yang,Tingkuan Chen
DOI: https://doi.org/10.1016/j.nucengdes.2008.10.026
IF: 1.7
2009-01-01
Nuclear Engineering and Design
Abstract:Within the range of pressure from 9 to 30MPa, mass velocity from 600 to 1200kg/(m2s), and heat flux at inner wall from 200 to 600kW/m2, experiments have been performed to investigate the heat transfer characteristics of steam-water two-phase flow in vertical upward tube. The outer diameter of the tube is 32mm, and the wall thickness is 3mm. Based on results, it was found that Dryout is the main mechanism of the heat transfer deterioration in the sub-critical pressure region. Near the critical pressure, when the heat transfer deterioration occurs, the steam quality of water is lower than that in the sub-critical pressure region, so that DNB is the main mechanism in this pressure region. At supercritical pressure, the heat transfer performance in circular channel is improved and enhanced. Heat transfer deterioration phenomenon is observed when the fluid bulk temperature approaches to the pseudo-critical value. Nusselt correlation of the forced-convection heat transfer in supercritical pressure region has been provided, which can be used to predict heat transfer coefficient of the vertical upward flow in tube.
What problem does this paper attempt to address?