Beam pulsing system for the 4.5MV electrostatic accelerator at Peking Univ

Jianqin L��,Shengwen Quan
1995-01-01
Abstract:A self-made single-stage 4.5MV electrostatic accelerator was designed and constructed at Peking Univ, P.R.China. In order to measure the neutron energy with the flight-time method, it is necessary to compress the continuous ion beams into the pulsed beams, hence a beam pulsing system was incorporated in this machine. In this paper, the 9 MHz rf bunching system, the 1.5 MHz rf chopping system, and the relevant electronic circuits of the beam pulsing system, as well as the requirements on the transverse focusing system, and on the simulations of particle's longitudinal motion were introduced with stress. The experimental results obtained from this beam pulsing system show that the achievable duration of beam-pulse width at the target is of 1.8ns.
What problem does this paper attempt to address?