Safe Stop-Pulsing Strategy for IGCT-based Three-Level Neutral Point Clamped Inverters

Liqiang Yuan,Guangyu Li,Zhengming Zhao,Ting Lu,Fanbo He,Fei Kong
DOI: https://doi.org/10.1109/icems.2013.6713298
2013-01-01
Abstract:Nowadays, the multi-level inverters are widely applied in the high power industrial areas. The direct stop-pulsing method is usually executed during inverters' normal halt and protection operation, whose reliability is proved in two-level inverters. However, this paper reveals that the direct stop-pulsing method brings risks of over-voltage for switch devices in some multi-level topologies. Regarding this direct method, this paper shows the damaged devices equipped in the 500kW/3.3kV inverter, analyzes commutating mechanism, and represents the actual process in low power experiments. Then, we proposes a safe stop-pulsing strategy for three-level inverters considering the blocking-delay time, the minimum width and the transition of pules. The control flow, determination of key parameters, hardware implementation and related experimental study is described in details.
What problem does this paper attempt to address?