Field measurement of temperature and stress on steel structure of the National Stadium and analysis of temperature action

罗尧治,梅宇佳,沈雁彬,杨鹏程,金砺,张鹏飞
DOI: https://doi.org/10.14006/j.jzjgxb.2013.11.005
2013-01-01
Abstract:With the aid of self-developed wireless sensors of structural stress and temperature, long-term measurement of stress and temperature was applied to steel structure of the National Stadium. Based on the measured data, this paper analyzes the distribution of the temperature field, and according to the non-uniformity of the temperature field, the actions of temperature field consists of two parts, uniform and non-uniform. Then this paper studies the performance of the structure under temperature action, during which a comparison was made between the actions of uniform and non-uniform temperature field. With the measured data throughout a whole year, it is indicated that: 1) there is obvious difference between different parts of the structure, and also, the temperature of the structure differs from the air temperature; 2) the stress variation was notable under uniform temperature field action, and the member stress is linear to its temperature; 3) the non-uniform temperature field makes the stress variation grow larger. At some parts such as the top chords, stress variation caused by non-uniform temperature field is larger than that caused by uniform temperature field action.
What problem does this paper attempt to address?