An experimental study of technical measures for energy saving of CNG compressors

Liang Zheng,Li Shuangshuang,Tian Jialin,Zhu Xiaohua,Mei Qinggang,Zhang Liwen
DOI: https://doi.org/10.3787/j.issn.1000-0976.2013.02.019
2013-01-01
Abstract:For lack of intensive studies and advanced techniques, unreasonable flow process and poor performance of CNG compressors have resulted in high energy consumption and low working efficiency, which have restricted the development of CNG filling stations in China. In view of this, this paper aims to study how to improve the efficiency and reduce the energy consumption of a CNG compressor, which is the most energy consumption unit of a CNG filling station. Thus, a study was made on what key parameters have impact on the efficiency of a compressor and what technical measures should be taken. Based on the compressing process, the transformation schemes were presented of cooling and separating the return gas between the stages of pipe loops. In a pilot test performed on an L-12/5-250 compressor, a cooler was installed in the intersage line between the second and the fourth pipe loops and the evaluation test was also made subsequently on the energy saving effect. Only when the intake pressure of inlet feed gas was adjusted at 0. 35, 0. 38, 0. 40 MPa respectively and with no any other changes ever done on the same compressor, the operating parameters and energy consumption data were recorded and compared between two working conditions when the installed cooler was on and off. As a result, the energy consumption of the compressor with the cooler on was saved by 3. 87%, 4. 04%, 3. 96% accordingly, which verifies the feasibility of the above transformation schemes.
What problem does this paper attempt to address?