Hydrogen performance of fiber Bragg grating hydrogen sensors using Pt-loaded WO3 coating as sensing materials

Jixiang Dai,Minghong Yang,Zhi Yang,Zhi Li,Yao Wang,Yi Zhang,Zhi Zhuang
DOI: https://doi.org/10.1117/12.2031098
2013-01-01
Abstract:A novel method was proposed to improve hydrogen sensitive performance of fiber Bragg grating (FBG) hydrogen sensor. The hydrogen performance of the sensor can be greatly improved by combining Pt/WO3 composite film annealed under 315 degrees C for 1 h and temperature sensitive FBG. At room temperature of 25 degrees C, FBG coated with Pt/WO3 composite film has 536 pm wavelength shift towards 10000 ppm hydrogen, and hydrogen detection threshold of FBG hydrogen sensor can reach to 200 ppm. The hydrogen performance of FBG hydrogen sensor was studied under different humidity, and ambient humidity has little effect on the hydrogen performance of FBG hydrogen sensor.
What problem does this paper attempt to address?