Fiber Optical Hydrogen Sensor Based on WO3-Pd2Pt-Pt Nanocomposite Films

Jixiang Dai,Yi Li,Hongbo Ruan,Zhuang Ye,Nianyao Chai,Xuewen Wang,Shuchang Qiu,Wei Bai,Minghong Yang
DOI: https://doi.org/10.3390/nano11010128
IF: 5.3
2021-01-08
Nanomaterials
Abstract:In this paper, WO3-Pd2Pt-Pt nanocomposite films were deposited on a single mode fiber as the hydrogen sensing material, which changes its reflectivity under different hydrogen concentration. The reflectivity variation was probed and converted to an electric signal by a pair of balanced InGaAs photoelectric detectors. In addition, the performance of the WO3-Pd2Pt-Pt composite film was investigated under different optical powers, and the irrigating power was optimized at 5 mW. With the irrigation of this optical power, the hydrogen sensitive film exhibits quick response toward 100 ppm hydrogen in air atmosphere at a room temperature of 25 °C. The experimental results demonstrate a high resolution at 5 parts per million (ppm) within a wide range from 100 to 5000 ppm in air. This simple and compact sensing system can detect hydrogen concentrations far below the explosion limit and provide early alert for hydrogen leakage, showing great potential in hydrogen-related applications.
materials science, multidisciplinary,physics, applied,nanoscience & nanotechnology,chemistry
What problem does this paper attempt to address?
### Problems the Paper Attempts to Solve This paper aims to address the issue of real-time hydrogen detection and proposes a fiber optic hydrogen sensor based on WO₃-Pd₂Pt-Pt nanocomposite thin films. Specifically, the paper attempts to solve the following aspects: 1. **Safety Detection of Hydrogen Leaks**: - Hydrogen, as a clean energy source, has great application potential, but its flammability and small molecular size make it very dangerous. Additionally, hydrogen has a wide explosion limit range (4% to 75%), and any leakage could lead to severe casualties and facility damage. - Therefore, developing a reliable and intrinsically safe hydrogen sensor is crucial for real-time monitoring of hydrogen concentration. 2. **Issues with Existing Sensors**: - Commercial electrochemical hydrogen sensors may trigger explosions due to potential electric sparks. - Fiber optic hydrogen sensors use optical fibers to transmit weak light signals, avoiding the use of electrical signals in flammable and explosive environments. Moreover, fiber optic hydrogen sensors are less susceptible to electromagnetic interference compared to electrochemical hydrogen sensors. 3. **Improving Detection Performance**: - A compact fiber optic hydrogen sensing system is proposed, using two InGaAs photodetectors to reduce the impact of light source fluctuations on measurement results. - A WO₃-Pd₂Pt-Pt nanocomposite thin film is deposited at the fiber tip to enhance the response capability of the sensing probe. The WO₃ film serves as the base layer, Pd₂Pt as the catalyst layer, and Pt as the protective layer, thereby improving the stability of the hydrogen-sensitive film. With these improvements, the sensor can quickly respond to 100 ppm of hydrogen at room temperature and achieve high resolution (5 ppm) in the range of 100 ppm to 5000 ppm in the air. This simple and compact sensing system can detect hydrogen concentrations far below the explosion limit and provide early warnings for hydrogen leaks, demonstrating significant application potential in related fields.