Hydrogen sensing performance investigations with optical heating and sensing element surface modification

Zhuang Ye,Zhi Li,Jixiang Dai,Yuhuan Qin,Gaopeng Wang,Zihui Yuan,Minghong Yang
DOI: https://doi.org/10.1016/j.ijhydene.2020.09.140
IF: 7.2
2021-01-01
International Journal of Hydrogen Energy
Abstract:<p>Fiber optic hydrogen gas sensors with low detection limit and high precision are highly demanding nowadays. Self-referenced fiber Bragg grating (FBG) hydrogen gas sensor offers promising advantages due to its improved systemic stability and compactness. Nevertheless, the low sensitivity and the low stability of hydrogen sensitive materials still greatly limit its detection capability in extremely low concentration range. Here we demonstrate that an improved self-referenced FBG hydrogen gas sensor design can overcome this limitation. It is based on an integrated architecture which combines a FBG structure coated with polyaniline modified WO<sub>3</sub>–PdPt composite film and an optical heating device using a high-power laser source. Due to the higher working temperature and the protective coating structure of the PdPt catalytic layer, the sensor shows faster response and higher measurement stability, which together results in a significantly low detection limit down to 4.5 ppm in air. These greatly improved sensing hydrogen gas performances highlights its promising applications in future.</p>
energy & fuels,electrochemistry,chemistry, physical
What problem does this paper attempt to address?
The paper aims to address the issue of insufficient detection capability of hydrogen sensors in extremely low concentration ranges. Specifically, the research team designed an improved Fiber Bragg Grating (FBG) hydrogen sensor, combining system optimization and material modification methods to enhance its detection sensitivity and stability at extremely low concentrations. The design of the sensor mainly includes the following two aspects: 1. **Optical Heating Device**: By locally heating the sensor element with a high-power laser source, the operating temperature is increased, thereby accelerating the chemical reaction process and removing moisture adsorbed on the coating surface, enhancing the sensor's response speed and measurement stability. 2. **Polyaniline Modification**: A polyaniline coating is added to the WO₃-PdPt composite film to protect the catalytic layer from oxidation, improving its long-term stability and catalytic performance. Experimental results show that this new type of sensor has a hydrogen detection limit in air as low as 4.5 ppm, demonstrating excellent sensing performance and broad application prospects.