A study of flow accelerated corrosion at elbow of carbon steel pipeline by array electrode and computational fluid dynamics simulation

Guoan Zhang,Lijiao Zeng,Hualiang Huang,Xingpeng Guo
DOI: https://doi.org/10.1016/j.corsci.2013.08.022
IF: 7.72
2013-01-01
Corrosion Science
Abstract:•Flow accelerated corrosion at elbow is studied by array electrode technique.•The fluid dynamics is determined by computational fluid dynamics (CFD) simulation.•The corrosion rate at the inner wall is higher than that at the outer wall of elbow.•The measured corrosion rates at elbow are in accordance with CFD simulation.
What problem does this paper attempt to address?