Design of standard head-mounted display for test system calibration

王鹤 wang he,孙强 sun qiang,宋淑梅 song shumei,李淳 li chun,李灿 li can
DOI: https://doi.org/10.3788/CO.20120505.0505
IF: 1.1
2012-01-01
Chinese Optics
Abstract:To calibrate the test instrument of a Head-Mounted Display(HMD) , a standard HMD optical system with a simple configuration and ascendant optical performance is proposed. In the limited space avoilable, the optical system is designed with only a spherical surface and an on-axial scheme to meet the requirements of low distortion and high resolution. By the symmetry principle of optical design, most aberrations of the stand- ard HMD system can be corrected synthetically. The standard HMD system is used twice so that the system has a sharp exit pupil. The standard HMD system has a designed for a 0. 5 inch Cathode Ray Tube(CRT) with a field of view 30° and an exit pupil distance of 75 mm. The MTF at 30 lp/mm resolution across the entire field of view is more than 0. 3, and the maximum distortion is less than 0. 9%. The designed standard HMD has a simple layout and compact structure, and the obtained results confirm the feasibility of the new system.
What problem does this paper attempt to address?