Quantification of Endostar in Rat Plasma by Lc-Ms/Ms and Its Application in A Pharmacokinetic Study

Ying Chun Li,Yan Liang,Zhi Yuan Tang,Ya Nan Xiao,Hai Ping Hao,Guang Ji Wang
DOI: https://doi.org/10.1016/j.jpba.2012.07.017
IF: 3.571
2012-01-01
Journal of Pharmaceutical and Biomedical Analysis
Abstract:LC-MS/MS is a promising analytical platform for the quantification of recombinant therapeutic proteins in biological fluids for pharmacokinetic (PK) studies. Herein, an absolute quantification method based on LC-MS/MS technique was developed to quantify endostar, which is modified from the recombinant human endostatin by adding a nine-amino acid sequence (MGGSHHHHH) at the N-terminal. A reproducible three-step analytical procedure was adopted: (1) Ni(2+) Sepharose was used to selectively extract endostar; (2) the signature peptide "TEAPSATGQASSLLGGR" (m/z 802.3(2+)-651.8(2+)) of endostar and a synthetic peptide "TEAPSATGQVSSLLGGR" (m/z 816.9(2+)-666.4(2+)) as internal standard (IS) were selected and analyzed in the multiple reaction monitoring (MRM) mode; (3) the proposed method was validated and applied to the pharmacokinetic study of endostar. The lower limit of quantification (LLOQ) for quantifying endostar was 50 ng/ml and this method is linear over 50-10,000 ng/ml. The accuracy was between 85% and 115%, and the intra-batch and inter-batch analytic precision and accuracy were below 15%. This LC-MS/MS approach was validated for the application to the pharmacokinetic study of endostar in rats.