Development, validation and application of a UHPLC-MS/MS method for quantification of the adiponectin-derived active peptide ADP355 in rat plasma

Qiaoxi Li,Fulin Jiang,Yanping Guan,Xianxing Jiang,Junyan Wu,Min Huang,Guoping Zhong
DOI: https://doi.org/10.1002/bmc.5358
Abstract:A UHPLC-MS/MS method for the quantification of ADP355, an adiponectin-derived active peptide, was developed and validated. The extraction method employed simple protein precipitation using methanol and chromatographic separation was achieved on anAccucore™ RP-MS C18 column (100 × 2.1 mm, 2.6 μm, 80 Å), using 0.1% formic acid in both water and acetonitrile with gradient elution at the flow rate of 400 μl/min within 4.0 min. Detections were performed under positive ion mode with multiple reaction monitoring ion transitions m/z 1109.2 → 309.8 and 871.4 → 310.1 for ADP355 and Jt003 respectively at unit resolution. The linearity range of the calibration curve was 2-1,000 ng/ml with a lower limit detection of 0.5 ng/ml. The selectivity, linearity, precision, accuracy, recovery, matrix effect and stability were validated, and all items met the requirement of US Food and Drug Administration guidance. This method was successfully applied to an intravenous pharmacokinetic study of ADP355 in rats and the in-vitro stability in rat serum, plasma and whole blood was also assessed.
What problem does this paper attempt to address?