Experimental Measurement of Gas-Solid Two-Phase Flow of a Swirl Burner by Optical Wave Method

周昊,吴剑波,杨玉,李亚鹏,胡善涛,岑可法
DOI: https://doi.org/10.3785/j.issn.1008-973x.2012.12.008
2012-01-01
Abstract:In order to measure the particle concentration and diameter distribution precisely,the principles of particle concentration measurement by the optical wave method were firstly introduced,and then the method was employed to investigate the particle concentration out of a swirl burner on a gas-solid test rig.The scale of recirculation zone,particle diffusion characteristics and particle concentrations in the flows at different cross-sections under various primary air and secondary air ratios were measured.The test results show that the zones of high solid-phase mass fraction are overlapped by those of high gas velocity,and all these zones are located close to exit of secondary air.Within 0-200 mm to the outlet of swirl burner,the attenuation of gas velocity is fast while the solid-phase mass fraction has little change.The influences of each air on particle distributions are different.Primary air has little influence on the concentration in the recirculation zone,but affects the peripheral region greatly.The enhancing of the inner secondary air will increase the concentration differences in the recirculation zone.The enhancing of the outer secondary air would limit particles external diffusion,resulting in the concentration distribution well-distributed at circumferential direction.