Experimental study on bearing capacity of welded H-section columns using Q460 high strength steel under bending and axial compression

李国强,闫晓雷,陈素文
DOI: https://doi.org/10.14006/j.jzjgxb.2012.12.007
2012-01-01
Abstract:This paper presented a study on the ultimate bearing capacity of high strength steel columns under eccentric load.Through the tension coupon tests and the measurement of the residual stress of H-section,initial geometric imperfections and ultimate loads of each column,tests on six specimens of welded H-section columns with three different cross sections made by Q460 high strength steel were conducted.The measured ultimate loads were compared with the values predicted by design formulas specified in Chinese codes.FEA models were employed to simulate the results of the tests.Initial deficiencies including geometric imperfection and residual stress were considered in the FEA models.The distribution of the residual stress and the material properties used in FEA models were taken from the tests.Q460 low alloy steel has high strength and high performance plastic property.The distribution of the residual stress of welded H-section columns using Q460 high strength steel and the distribution of the residual stress using ordinary steels were basically identical.The experimental results show that the bearing capacity of welded H-section columns of high strength steel are higher than the values predicted according to the Chinese code for design of steel structures.The results predicted by FEA models fit well with those obtained from the tests.This study provides the basis for the application of Q460 high strength steel in practical engineering.
What problem does this paper attempt to address?