Investigation of Sleep Quality under Different Temperatures Based on Subjective and Physiological Measurements

Li Pan,Zhiwei Lian,Li Lan
DOI: https://doi.org/10.1080/10789669.2012.667037
2012-01-01
HVAC&R Research
Abstract:This study investigated sleep quality at different indoor temperatures (17 degrees C, 20 degrees C, and 23 degrees C [62.6 degrees F, 68.0 degrees F, and 73.4 degrees F]) via subjective and physiological methods by evaluating the thermal comfort and sleep quality before and after sleep. Electroencephalograms were also obtained, and skin temperatures were measured throughout the entire sleep cycle. The quantitative powers of each electroencephalogram frequency rhythm were calculated, and the duration of every sleep stage was determined. Both results show that the ambient temperature has a significant effect on sleep quality. The subjective results show that 20 degrees C (68.0 degrees F) was the most comfortable temperature for the waking state and 23 degrees C (73.4 degrees F) was the most satisfactory temperature for sleeping. The objective results show that at 23 degrees C (73.4 degrees F), the relative power of the sleep delta band was the highest, the duration of sleep onset latency was the shortest, and the slow-wave sleep was the longest. All these results were highly consistent, indicating that sleep quality was highest at 23 degrees C (73.4 degrees F). The higher thermal comfort temperature in sleep compared with that in the waking time may be due to the lower mean skin temperature during sleep.
What problem does this paper attempt to address?