Performance of vibration-controlling suspended-floor structures based on characteristics of earthquake motions

Chunlin Wang,Zhitao Lü
DOI: https://doi.org/10.3969/j.issn.1001-0505.2012.04.027
2012-01-01
Abstract:The influence of the earthquake motions on the responses of the suspended-floor building are evaluated. First, based on the structural features, its numerical model was built. Secondly, time history analyses were employed to evaluate the effect of characteristics of earthquake motions on the controlling results of the suspended-floor structures under near-fault and far-fault earthquakes. Finally, the influence of the locations of the dampers was addressed. Numerical results show that the optimum damping coefficient of dampers can be obtained to minimize dynamic responses of the core-tube under near-fault and far-fault earthquakes and the optimum values are nearly identical in spite of the different features of earthquake motions. Moreover, under near-fault earthquakes, dynamic responses of the core-tube are relatively large but the vibration-controlling effect is small. The relative displacement of suspended floors to the core-tube and the story drift of suspended floors can be well constrained when the dampers are used to link the suspended floor with the core-tube. However, the relative displacements of suspended floors under near-fault earthquakes are larger than those under far-fault earthquakes. If the total quantity of dampers is given, the triangle or basic-mode distribution patterns of dampers are better than the uniform distribution pattern, the former would be beneficial to better controlling effect and decrease relative displacements of suspended floors.