Hydrogen Performance of Side-Polished Fiber Bragg Grating Sputtered with Pd/Ag Composite Film

Jixiang Dai,Minghong Yang,Yun Chen,Kun Cao,Junsheng Liao,Pengcheng Zhang
DOI: https://doi.org/10.1166/sl.2012.2473
2012-01-01
Sensor Letters
Abstract:Pd/Ag composite films are deposited on the side-face of side-polished fiber Bragg grating as sensing elements by magnetron sputtering process. The atomic ratio of the two metals is controlled at Pd:Ag = 76:24. Compared to standard FBG coated with same hydrogen sensitive film, side-polished FBG significantly increases the sensor's sensitivity. When hydrogen concentrations are 4% in volume percentage, the wavelength shifts of side-polished FBG are 8 and 18 pm respectively. The experimental results show the sensor's hydrogen response is reversible, and the hydrogen sensor has great potential in hydrogen's measurement.
What problem does this paper attempt to address?