Shock Calibration for a High-G Accelerometer Using a Laser Interferometer

FAN Jin-biao,ZU Jing,LIN Zu-sen,XU Peng,ZHAO Xiao-dong
DOI: https://doi.org/10.3969/j.issn.1000-3835.2012.11.031
2012-01-01
Abstract:Based on analysis of the reflecting type laser Doppler principle,a method for shock calibration of a high-g piezoresistive accelerometer was studied here.A Hopkinson bar was used to generate an excited acceleration pulse absolutely measured using a differential laser interferometer.A set of calibration tests was conducted for a high-g accelerometer SIMIT-AYZ-60k.The shock sensitivity of the accelerometer was calculated with the quasi-dynamic calibration data using the least square method.It was demonstrated that this method is effective for shock calibration of high-g accelerometers whose natural frequencies are above 20kHz using the excited pulse with a definite duration;the calibration accuracy is adequate to meet the requirements of engineering measurement.
What problem does this paper attempt to address?