Experimental study on the ultimate bearing capacity of axially compressed high strength steel of H-section columns

Yanbo Wang,Guoqiang Li,Suwen Chen,Feifei Sun
2012-01-01
Abstract:An experimental study on the ultimate bearing capacity of axially compressed H-section columns of high strength steel is presented. Six H-section columns with 3 differently sized cross sections were tested to failure under axial loading. Specimens were welded from 11mm-thick web plates and 21 mm-thick flange plates of Q460 high strength steel made in China. Numerical models were established according to measured sizes of the members and the tension coupon test results. Initial geometric imperfections and the residual stress obtained from the accompanied residual stresses test were taken into account in the numerical analysis. According to GB 50017-2003 Code for design of steel structures, the experimental result shows that type b buckling curve is appropriate for welded flame-cut H-section columns of Q460 high strength steel. The numerical result with consideration of the effect of both residual stresses and geometric imperfections agrees well with the experimental result. Finally, further numerical calculations based on the measured residual stresses and assumed geometric imperfections are recommended as a supplement of the limited test data.
What problem does this paper attempt to address?