Study on Water Permeability of UHTCC

徐世烺,高栋,李庆华
DOI: https://doi.org/10.13243/j.cnki.slxb.2012.s1.017
IF: 2.4
2012-01-01
Journal of Hydraulic Engineering
Abstract:As a kind of new green building materials, Ultra High Toughness Cementitious Composites (abbreviated as UHTCC) shows prominent toughness and superior durability. Tension load was imposed on UHTCC specimens till the tensile strain reaches 1.5%, 2%, 2.5%, respectively. Then water permeability of UHTCC with micro-cracks was investigated. The results show that, within 40μm~70μm width micro-cracks, UHTCC still has a good anti-permeability. Permeability of UHTCC increases with the increase of crack width. When the average crack width is between 40μm and 45μm, the corresponding permeability coefficient is 2.17225×10-10~3.86467×10-10m/s, and the average permeability coefficient of each crack is 3.91815×10-12~5.76816×10-12m/s. Measured by relative penetration height method, the permeability coefficient of cracked UHTCC is similar to that of non cracked C30 concrete. When the thickness is more than 12mm, UHTCC has excellent crack dispersion ability, and a better anti-permeability compared with specimens with 10mm thickness. At last, this paper established the relationship between permeability coefficient and average crack width.
What problem does this paper attempt to address?