Effect of Needle Curvature and Aluminum Foil Size on Discharge Mechanism Under Needle-plate Configuration

秦楷,潘成,吴锴,孟永鹏,成永红,黎大健
DOI: https://doi.org/10.3969/j.issn.1003-6520.2012.07.036
2012-01-01
Abstract:It is necessary to investigate the gap breakdown which is usually caused by non-uniform electric field in the electrical set-ups. Consequently, we constructed a measurement system for detecting ns discharge current pulse during partial discharge {PD) to study the effect of the variation of needle curvature and aluminum foil size on the discharge parameters. When the dielectric surface was not covered by aluminum foil , the peak value of current pulse increased ,and its rise part, falling part, and pulse width decreased as the needle curvature increased. The peak value of positive discharge current was higher than that of negative one, and that of its slew and falling part was lower than that of negative one, which could be well explained by the streamer theory. As the area of aluminum foil increased, the peak value and rise part of current pulse increased, and the falling part and pulse width decreased. However, the abnormal phenomenon for negative discharge was found that minimum rise part appeared with relatively small diameter of aluminum foil {5 mm). With the aluminum foil covering the dielectric surface, the similar result was obtained when the curvature radius was smaller. As curvature radius increased, the pulse width of negative discharge was smaller and its current peak value was larger compared with that of positive discharge. Accordingly, the combination of larger curvature radius and aluminum foil leaded to the transition of discharge mechanism, which was different from streamer.
What problem does this paper attempt to address?