FAIMS Biochemical Sensor Based on MEMS Technology
Fei Tang,Xiaohao Wang,Chulong Xu
DOI: https://doi.org/10.5772/16814
2011-01-01
Abstract:Introduction 1.1 The research background of FAIMSTo build a resource-conserving and environmentally friendly society is a strategic mission in the long-term plan of a national economy and society development.Environmental protection regulation, is not only about preventing pollution and protecting ecosystem, but also includes the fast detection of environmental pollutants.Thus, analytical apparatus for the fast and effective detection of environmental pollutants is required.Besides, the realtime detection technology of the trace amounts of chemicals, drug, explosive material, etc. is also an important technical method to maintain people's health, social stability and national security.At present, common detection methods use complex, expensive and bulky detection equipment or have complex procedures without portability, which limits their use.For example, methods like mass spectrometry, atomic fluorescence and so on need complex instruments.In contrast, titration and colorimetry only need simple equipment, but their process of operation is complex, which leads to time-consuming, low efficiency and highly demanding operations.So these kinds of methods are hard to promote.With the increasing demand in application, portable and low power consuming microchemical analysis detection instruments are urgently required.Ion Mobility Spectrometry (IMS), which plays a very important role in the detection of explosive substances, poison and chemical warfare agents, etc., was developed during the 1970s.In IMS, substances are separated mainly according to differences in the mobility of ions under low electric fields in order to analyse each kind of the substance.Up until now, many kinds of commercial IMS have appeared, which have been widely used in detection of the environmental pollutants, explosive materials, drug and chemical warfare agents, etc. (West et al., 2007;Laiko et al., 2006;Borsdorf et al., 2006).The drift tube of IMS is a metal ring structure, which is adverse to miniaturisation (Miller et al., 2001).In the high-field asymmetric waveform ion mobility spectrometry (FAIMS) developed in recent years, the drift tube is a flat plate structure, which makes it easy to fabricate with Micro Electro Mechanical Systems (MEMS).It has many strengths, such as miniature size, high sensitivity, short test time, numerous test substances, low power usage, etc.So it can be used to detect substances instead of IMS.In addition, substances of same or similar ion mobility under the conditions of the low electric field which are hard to separate in IMS, can be separated by the difference in the ion mobility in the high electric field of FAIMS (Miller et al., 2000).On the other hand, FAIMS can be used together with a mass spectrograph, and can bring ion filtration and selection to the mass spectrograph, resulting in decreased background noise and improved signal to www.intechopen.com