Dosimetry of Technegas in lung ventilation studies

LI Bei-lei,CHEN Shao-liang,李蓓蕾,陈绍亮,刘文官
DOI: https://doi.org/10.3760/cma.j.issn.2095-2848.2007.06.013
2007-01-01
Abstract:Objective Techenegas is an uhra-fine dispersion of carbon aggregates labeled with ~(99)Tc~m developed for lung ventilation scanning.The purpose of this study was to investigate the dosimetry of Technegas in healthy volunteers.Methods In 8 healthy volunteers a single inhalational dose of(46.71± 19.02)MBq was administered.Biodistribution was assessed for up to 24 h by a gamma camera.The counts from ROIs were obtained over the critical organs.The residence of activity in each critical organ and whole- body were computed via the area under their time-activity curves.The medical internal radiation dose (MIRD)formulation was used to calculate the absorbed radiation dose for various organs.Results On av- erage,The highest absorbed dose was received by lung [(9.8±1.2)×10~(-2)mGy/MBq] followed by stom- ach [(1.7±1.2)×10~(-2)mGy/MBq],heart wall [(1.2±0.17)×10~(-2)m Gy/MBq],thyroid[(8.3± 5.9)×10~(-3)mGy/MBq],liver[(7.8±2.8)×10~(-3)mGy/MBq]and kidney [(7.6±3.0)×10~(-3)mGy/ MBq].The estimated mean effective dose was(1.6±0.37)×10~(-2)mSv/MBq.Conclusion Although the ef- fective absorbed dose of Teehnegas is much higher than ~(99)Tc~m-DTPA aerosol,~(81)Kr~m and ~(133)Xe,it results in an acceptable effective dose to the patient according to the recommended dose constraints of adult volunteers in biomedical research(WHO)and risk categories stated in International Commission on Radiological Pro- tection(ICRP)62.
What problem does this paper attempt to address?