Organ Dose Estimation for Adult Chest CT Examination Using GATE Monte Carlo Simulation

M. Tahiri,M. Mkimel,Y. Benameur,R. El Baydaoui,M. R. Mesradi,O. El Rhazouani
DOI: https://doi.org/10.1134/S1547477121040166
2021-08-03
Physics of Particles and Nuclei Letters
Abstract:— This work relates to the study of organ dose during a Chest computed tomography (CT). Organ dose has been simulated with the Monte Carlo Simulation code (GEANT4/GATE) using two computational phantoms Adam male and Eva female. Simulated scans were performed for helical mode, collimation of 10 mm and tube voltages of 80, 110 and 130 kV. The method "dose by region" used in GATE to calculate the organ doses was validated with maximal agreement of 7%. Organ doses for Adam and Eva were evaluated and contributions to effective dose were compared to those obtained from IMPACT CT and CT-EXPO. It was found that Eva lungs were more irradiated than Adam by averaged difference of 3 mGy. For breasts absorbed dose, the tube voltage increase effect (80–130 kV) was estimated to be around 71%, 74 and 86% for this study, CT-EXPO and IMPACT CT respectively. The largest contributions to effective dose were from remainder tissues (29%), lungs (27%) and breast (21%). Generally, the results show that organ doses obtained from software exceeded those from GATE simulations. This work attests the ability to assess organ dose by using a GATE "dose by region" actor, as well as, evaluates organ dose estimation errors inducted by commercial software.
What problem does this paper attempt to address?