Imaging and Studying Human Topoisomerase I on Mica Surfaces in Air and in Liquid by Atomic Force Microscopy

Zhiguo Liu,Ronghua Meng,Yuangang Zu,Qingyong Li,Liping Yao
DOI: https://doi.org/10.1002/sca.20154
2009-01-01
Scanning
Abstract:In this study, the topography of human topoisomerase I (TOPO I) on mica surfaces in air and in liquid has been studied by atomic force microscopy (AFM). The average height of TOPO I on mica surface in air measured by AFM was 2.59+/-0.32 nm. After adsorption of the 0.3 U/microl TOPO I on mica surfaces for 2 h, and then imaged in liquid by AFM, well-separated single TOPO I was observed. The average height of TOPO I on mica surfaces in liquid measured by AFM was 2.93+/-0.42 nm. After adsorption of the 4 U/microl TOPO I on mica surfaces for 1.5 h, TOPO I monolayer can be formed. The produced TOPO I monolayer on mica was flat and exhibited good stability.
What problem does this paper attempt to address?