Design of Cover-Plate-retrofitted Steel Moment Connections with Pre-Existed Loads

YANG Wen,SHI Yong-jiu,WANG Yuan-qing,SHI Gang
DOI: https://doi.org/10.3969/j.issn.1673-9469.2005.04.011
2005-01-01
Abstract:Finite element analysis is employed in this paper to simulate the process of retrofitting steel moment connections with some pre-existed loads and to investigate the loading capacity of retrofitted connections.The influences of the pre-existed loads and the geometrical parameters of cover-plates on the loading properties of the retrofitted connection have been discussed,and the cooperation of the cover-plate and the original connection has been analyzed.It has been observed the pre-existed load was sustained by the original connection,and the additional load was distributed proportionally between the original connection and the cover-plate.Therefore the design of the retrofitted connection as an entire one is not suitable any more.By the means of parameter analysis,the results have also indicated that significant differences of the moment distribution between the cover-plate and the original connection occurred as the change of the cover-plate thickness but the different lengths of the cover-plates caused no discrepancy.As well,the design method in the case of retrofitting this type of connection with pre-existed loads has been proposed.
What problem does this paper attempt to address?