Measurement of Void Fraction in Vertically Rising Pipes by Using Optical Fiber Probes

YANG Sheng,LUO Yu-shan,Ting kuan Cheng,Feng Y. Cheng
DOI: https://doi.org/10.3321/j.issn:1000-6761.2006.06.024
2006-01-01
Abstract:A way of measuring the cross-sectional void fraction in vertically rising oil pipes by using quick closing valves and optical fiber probes has been researched.The functional relationship α=f(α_c),between the cross-sectional mean void fraction α of a oil-gas two phase flow in a vertically rising pipe and the local void fraction at pipe's center α_c,for different pipe diameters and varying oil flow,is established,followed by an exponential distribution model with reference to Bankoff's variable density model.The distribution of the local void fraction α_r along the pipe's radius is finally being studied.Results indicate that,under test conditions,α_r reduces in radial direction and the largest local void fraction appears at pipe's center.Figs 8 and refs 9.