Practical application of design and construction of steel shear walls

Shen Jin,Gan Gang,Tong Genshu
DOI: https://doi.org/10.19701/j.jzjg.2013.15.004
2013-01-01
Abstract:A practical application of steel shear walls is introduced.In order to keep as large as possible space for the elevator corridor,steel shear walls were used to replace the original steel diagonal bracing,the total width of the members is reduced from 800mm to 340mm,and the width of the corridor is increased.The procedure by which the diagonal bracings are equivalently converted into stiffened steel shear walls is introduced,the sizes of closed form stiffeners and the required distance between stiffeners are also presented for reference.The stress analysis of steel wall is introduced under gravity loads,and proposed a method for determining the effective load-carrying capacity for shear.
What problem does this paper attempt to address?