Steel Plate Shear Wall with Vertical Slips and Its Trial Application in a High-Rise Steel Frame Building Structure

ZHAO Zuozhou,XIAO Ming,KE Jianghua,HE Xiaogang,QIAN Jiaru,GUO Zhonghua,MA Bin
DOI: https://doi.org/10.14006/j.jzjgxb.2010.09.016
2010-01-01
Abstract:Test results of 12 specimens about one-fourth scaled steel plate shear wall with vertical slits specimens in 6 groups are presented in this paper.It is found that specimens with two layers of vertical slits all failed in a diagonal tension band mode due to buckling of the entire steel plate and behaved much better than the specimens with one layer of vertical splits.Based on the available test results and theoretical data,wall stiffness and strength calculation formula are proposed.The design procedure and seismic design principle are introduced for the application of steel plate shear walls with vertical slits in the Beijing Chang Fu Gong Hotel based on the criteria that steel plate shear drift ratio at yielding point should not be less than 1 /300.The nonlinear dynamic responses and amount of steel used between the new trial structure and the prototype one are compared,revealing that not only lateral stiffness of the whole structure but seismic behavior can be improved under feasible design and layout of the steel plate shear walls with vertical slits.The steel shear wall with vertical slits can easily be replaced if damaged in earthquake,and is promising as a high performance element for frame structures.
What problem does this paper attempt to address?