Study on Treatment of Wastewater from Cold Mill by Poly Ferric Chloride

林永增,王国栋,刘相华,朱诚
DOI: https://doi.org/10.3969/j.issn.1671-6620.2010.01.017
2010-01-01
Abstract:The wastewater from cold mill contains various pollutants so that it is regarded as a complex wastewater difficult to treat.Poly ferric chloride was prepared by oxidation of cold rolling acid waste at room temperature and applied in treating the wastewater from cold mill.The results showed that the coagulation effect was good resulting in removal of COD and suspended solid,and the sludge dewatering performance was improved.To treat 500 mL wastewater,the process conditions is: 1.5~2.0 mL poly ferric chloride,0.12~0.25 mL PAM,pH between 7~8 and 30 min precipitation time.The method was put into practice and is worthy of popularization to cut down pollution.
What problem does this paper attempt to address?