Treatment of cold rolling mill wastewater containing emulsified oil by coagulation-air floatation-anaerobic-aerobic process

Cheng Xuehang,Zhang Zhenjia
DOI: https://doi.org/10.3969/j.issn.1005-829X.2010.04.021
2010-01-01
Abstract:Coagulation-air floatation-anaerobic-aerobic treatment process has been applied to the treatment of cold rolling mill wastewater containing emulsified oil.The experimental results show that the coagulant combination of PAC,PFS and CPAM have the best capacity for emulsion breaking.The optimum dosage of PAC,PFS and CPAM are 80,800,15 mg/L respectively.The anaerobic system could remove about 70% of the COD at the optimum HRT of 48 h and COD volumetric loading of 0.5-0.6 kg/(m3.d).Sufficient alkalinity in the influent water is needed in order to keep pH at about 7.2.When DO is kept over 3.0 mg/L and HRT is over 27 h,the internal circulating contact oxidation tank in series after the anaerobic reactor achieves stable and good treatment performance.Thus,the effluent water can reach the Integrated Standard of Wastewater Discharge(GB 8978—1996).
What problem does this paper attempt to address?