Experimental investigation on anti-freeze behavior of plain concrete
FANGCongqi,ZHANGJunmeng,DUANGuizhen
DOI: https://doi.org/10.3969/j.issn.1002-3550.2014.02.002
2014-01-01
Abstract:In order to further study the antifreeze performance difference of confined concrete and plain concrete,in confined concrete model for reference,making the same ratio of plain concrete cubic block and under the same conditions were also tested under freeze-thaw cycle of different numbers as 0,20,40,60,100 and 120 times,As the second part,mainly analyzed the compressive strength of plain concrete under freeze-thaw test,mass loss of samples and water absorption performance changing with the number of freezing and thawing,and establish the freeze-thaw damage prediction model of concrete compressive strength and mass loss ratio.Experiment showed that with the increase of freeze-thaw cycles,the compressive strength of plain concrete decreased parabola,drying quality and full water mass linearly decreased,while water absorption decreased by double line.From the aspects of material level,fly ash had a greater influence on the loss of concrete compressive strength,mass loss rate and water absorption,while water cement ratio had little influence on the above indicators.The loss of compressive strength of mixing 15%fly ash concrete was about 20%to 30%higher than mixing no fly ash concrete;Mass loss rate was about 5%to 6%larger than not mixing fly ash ,fly ash is not conducive to the antifreeze performance of concrete.As the same fly ash,the loss of compressive strength,mass and bibulous rate in low water-cement ratio concrete changed lager than high water cement ratio.When using fly ash concrete,it is easy to reduce the water cement ratio.